DIVA D C24
4.6 Wiring diagram
Attention: Before connecting the room thermostat or remote timer control, remove the jumper on the ter-
A
minal block.
32
Heating circulating pump
42
DHW temperature sensor
44
Gas valve
72
Room thermostat (optional)
81
Ignition/detection electrode
95
Diverter valve
EN
fig. 19- Wiring diagram
114 Water pressure switch
126 Fume thermostat
136 Flowmeter
138 External probe (optional)
139 Remote timer control (optional)
278 Double sensor (Safety + heating)