Use a soft, clean cloth and detergent to remove stubborn marks
and dirt from the unit.
Store the unit in a safe, dry place away from heat and water.
CAUTION!
Repairs must be carried out by a professional technician,
unless otherwise specified by the supplier or manufacturer.
If the appliance has been in use for two hours, we recommend
waiting ten minutes before disconnecting the power cord.
This is beneficial to the longevity of the appliance.
Cleaning
General cleaning of the unit will extend its life. Keep the appliance
clean by dusting it regularly. Regular maintenance will prolong the life
of your appliance and prevent injuries! For more information, please
visit https://www.virtufit.nl/service/faq/
CAUTION!
Wear clean shoes to reduce the risk of soiling the
machine. At least once a year, remove the cover to remove dust.
TROUBLESHOOTING
The display does not show any values: Check that the sensor and
console cables are properly attached and undamaged. If this does not
solve the problem, carefully bend the sensor.
Exercise bike squeaks: Check that all bolts and nuts are tight. If
necessary, apply silicone spray.
Ticking noise when pedalling: This may be caused by one of the
pedals. Remove the pedal(s) and mount it (them) correctly on the unit.
Tighten the pedal(s) firmly. If this does not solve the problem, contact
the supplier.
NOTE!
The "R" (right) pedal must be mounted clockwise and the "L"
(left) pedal must be mounted counter-clockwise.
The hand sensors are not working properly: Wash your hands, dry
them well and test the hand sensors again. If this does not solve the
problem, check the handlebar cables for damage and ensure that they
are properly connected to the connector. If this still does not correct
the problem, replace the handlebar.
Console does not work: If there is no signal when pedalling, check that
the cable is correctly connected.
ERROR CODES
E1:
Motor does not work (motor problems)
Solution: This problem may be caused by the motor having
difficulty adjusting its resistance, resulting in a loud motor noise.
When this happens, the motor may be possibly damaged by a
malfunction. Change the resistor and try again. If this does not
solve the problem, check that the magnetic resistance system
is not damaged, that there is room to adjust it, and that the
gears mesh properly. Once the problem has been solved, check
that the motor is working properly. If this still does not solve the
problem, replace the motor.
There is a problem with the cables
Solution: Check that the cables are not damaged or that they
cannot cause a short circuit.
The console has a problem.
Solution: Replace the console
E2:
A problem with the cables
Solution: Make sure the cables are not damaged or have the
potential to short.
There is a problem with the console:
Solution: Replace the console.
There is a problem with the motor:
Solution: Replace the motor.
E3: There is a problem with the cables.
Solution: Make sure the cables are not damaged or short-
circuited.
E4: During the body fat analysis, the first 8 seconds do not detect
the heart.
Solution: Wash your hands, dry them well and retest the hand
sensors. Hold the handles firmly with both hands.