3. Installing the indoor unit
1
3
5
7
Fig. 3-1
950 D
20 – 45
860 – 910 C
795 B
145
193
222
G
F
E
Fig. 3-2
2
4
6
8
20 – 45
145
840 A
E
F
Min. 1500
H
Floor
3.1. Check the indoor unit accessories (Fig. 3-1)
The indoor unit should be supplied with the following accessories.
Accessory name
Installation template (top of the package)
1
Washers (with insulation)
2
Washers (without insulation)
Pipe cover (for refrigerant piping joint)
Small diameter
3
Large diameter
Band (large)
4
Band (small)
5
Drain socket
6
Insulation
7
Flare nut 1/4F (M60)
8
3.2. Ceiling openings and suspension bolt installation
(mm)
locations (Fig. 3-2)
Warning:
• This unit should be installed in rooms which exceed the floor space specified
in outdoor unit installation manual.
Refer to outdoor unit installation manual.
• Install the indoor unit at least 2.5 m above floor or grade level.
For appliances not accessible to the general public.
• Refrigerant pipes connection shall be accessible for maintenance purposes.
• Using the installation template (top of the package) and the gauge (supplied as an
accessory with the grille), make an opening in the ceiling so that the main unit can
be installed as shown in the diagram. (The method for using the template and the
gauge is shown.)
* Before using, check the dimensions of template and gauge, because they
change due to fluctuations of temperature and humidity.
* The dimensions of ceiling opening can be regulated within the range shown in
Fig. 3-2; so center the main unit against the opening of ceiling, ensuring that the
respective opposite sides on all sides of the clearance between them becomes
identical.
• Use M10 (3/8") suspension bolts.
* Suspension bolts are to be procured at the field.
• Install securely, ensuring that there is no clearance between the ceiling panel &
grille, and between the main unit & grille.
A Outer side of main unit
B Bolt pitch
C Ceiling opening
D Outer side of Grille
* Note that the space between ceiling panel of the unit and ceiling slab, etc. must be
7 mm or more.
*
When the optional casement is installed, add the value indicated in the following
table to C marked on the figure.
Models
M35-71
M100-140
Optional casement
Multi functional casement
Plasma Quad Connect
3D Total Flow Unit
Q'ty
E Grille
F Ceiling
G Optional casement
H Entire periphery
(mm)
A
B
241
258
281
298
(mm)
C
135
135
80
1
4
4
1
1
8
1
1
1
1
en
3