3.0 Before installation
3.1 Distance to inflammable material
See fig. 1A+1B.
3.2 Foundations
Make sure the floor is suitable for the entire installation. See «2.0
Technical Data» for specified weight.
Remember: If using a steel chimney that rests on the insert, the
weight of the steel chimney must be taken into account.
NB: It is extremely important to ensure that the product is stable.
It must be installed on a completely inflexible floor.
We recommend the removal of any flooring that is not attached
to the foundation («floating floors») from the installation area.
3.3 Floor plate
A plate made of steel or other suitable non-combustible material
is placed in front of the fireplace and possibly under the entire
installation.
The floor plate must comply with national laws and regulations.
Contact your local building authorities regarding restrictions and
installation requirements.
3.4 Air supply
There must be a flow of air between the burn chamber and the
surround. This is to prevent too much heat building up inside the
surround.
NB: It is extremely important not to cover air openings. See fig.
1A+1B for distances.
3.5 External air
A flexible supply hose allowing external air to be fed directly into
the product can be passed through:
The opening in the rear plate
The bottom plate's knockout.
See the manual for the product.
3.6 Steel chimney
If a top-mounted steel chimney is used, an uninsulated pipe is
fitted from the burn chamber to approximately 10 mm through
the top grate. Make sure that the gasket is properly seated
between the flue pipe and the smoke outlet. Then fit the steel
chimney in accordance with the chimney supplier's installation
instructions.
3.7 Ceiling
See «2.0 Technical Data».
(fig. 2).
4.0 Installation
The product is heavy! Ensure you have help when positioning
and installing it.
The product comes with three manuals:
1.
General use and maintenance instructions.
2.
Jøtul FS 280 Series (surround).
3.
Jøtul F 270 Series (burn chamber).
4.1 Preparations
The basic product comes in three packages:
1.
Burn chamber.
2.
Steel surrounding set.
3.
Leg console.
NB: Check that there is no visible damage to the product when you
unpack it, and make sure that the control handles move freely.
Before installation, it is necessary to decide on:
Where to have the smoke outlet. If rear outlet is selected, this
has to be changed at this stage.
Possible use and location of external air supply. See separate
manual for installation.
NB: The burn plates are made of a porous material (yellow
vermiculite) and may be damaged if they are handled roughly.
1. When the burn chamber is unpacked, the baffle plate and
riddling grate are removed.
2. Lift off the top plate with the air grid and bowl. The top plate
is not to be used.
3. Lift off the rear heat shield (cast iron). This hangs on 3 screws,
two above and one below. See fig. 3.
4.
Spread out the cardboard packaging on the floor, and put
the wooden pallet upon it. Lay the stove carefully on its back.
See fig. 4.
5.
Remove the four screws and take away the heat shield under
the burn chamber. This is not to be used.
4.2 Chimney and flue pipe
The fireplace can be connected to chimneys and flue pipes
approved for solid fuel fireplaces with flue gas temperatures
as specified in «2.0 Technical Data».
The cross-section of the chimney must be at least that of the
flue pipe. When calculating the correct chimney cross-section,
refer to «2.0 Technical Data».
Several solid fuel fireplaces can be connected to the same
chimney system if the chimney cross-section is adequate.
Contact your local building authorities regarding restrictions
and installation requirements.
Connection to the chimney must be performed in accordance
with the installation instructions of the chimney supplier.
Make sure that the flue pipe rises all the way up to the
chimney.
For recommended chimney draught, see «2.0 Technical Data».