Ambient conditions
Storage conditions
Operating conditions
Temperature
Room temperature
Outside temperature
Set temperature range
Calibration options
Control
Room control
Features of the controller
Date/time indication
Temperature: -25°C – 60°C
Relative humidity: 5% – 90% no condensation
Without batteries: 0°C – 60°C
With batteries: 0°C – 55°C
Measurement range: -5°C – 65°C
Maximum temperature deviation at 20°C: 0.3°C
The measurement is taken in the boiler and passed to the controller.
Consult the boiler documentation regarding the accuracy of the
measurement.
5 – 35°C
Inside- and outside temperature sensor: -5 to +5 in steps of 0.5°C
Modulating temperature control
The control can be optimised
Overshoot: maximum 1°C after pre-heating
Temperature variation: less than 0.25°C
Time: 24 h clock (accuracy: to about 365 seconds per year)
Date: day – month – year Automatic switching to summer time
EN