- Select the day(s) to which you want to copy the settings using button C and press Save.
6. Go to the day.
Then press button C.
7. Go to step 2 to set the next day, or press Back to close this menu.
Restoring the default settings
Select Menu > Program > Clock prog. > Factory settings to restore the settings for the default
clock program.
5.3 Setting continuous temperatures
Instead of the clock program, you can also set the room temperature continuously to a particular
value. You can set three different continuous temperatures via Menu > Program:
Day temp.: room temperature during the day, corresponding to the Continuous day program.
Night temp.: room temperature at night, corresponding to the Cont. night program.
Frost temp.: room temperature to protect the room where the controller is installed from
freezing. This setting comes under the Frost program.
The programs mentioned are explained in paragraph 6.1.
i
5.4 Group control
With the aid of the c-Mix, the controller can control two groups; both groups can be assigned their
own program and control strategy. This is done via: Menu > Settings > System > CH system >
Zoning the default setting is No zoning.
The option 1 & 2 separate can be used to assign each group its own program.