DC power
!
WARNING! Fire hazard!
• The supply line to the heating element must be protected with a
20 A fuse.
• The supply line to the electronics must be protected with a 2 A fuse.
A
NOTICE!
The respective positive and negative supply lines of the DC connections
for electronics (fig. j 23, page 11) and heating element (fig. j 24,
page 11) may not be joined with one another and carried on a single
wire. This can cause electrical interference or damage to electrical
components.
EN
Description
Display
Heating frame
Fan 2 (if options module is available)
Fan 1 (if options module is available)
Options module
DC supply oven (if options module is available)
DC supply options module
CI-Bus connection
DC power supply
12 V terminal housing (front view)
•
AMP/TE Tyco: 180906
•
CS Colombo: 63N025
DC supply cable electronics
DC supply cable heating element
Internal DC supply, max. 1 A (options module, oven, fan)
Connecting the refrigerator