Never use the machine with a damaged cable. Do not touch the
damaged cable and pull the mains plug when the cable is damaged
while working. Damaged cables increase the risk of an electric shock.
For further safety instructions, please refer to the enclosure!
Before starting the machine check the correspondence between voltage and
frequency according to the data mentioned on the identification plate. Voltage
differences from + 6 % and – 10 % are allowed.
The angle grinder is made in protection class II.
Only use extension cables with a sufficient cross-section. A cross-section which
is too small could cause a considerable drop in performance and an
overheating of machine and cable.
Recommended minimum cross sections and maximum cable lengths
Mains voltage
110V
230V
The tool is equipped with a start-up speed limiter to prevent that swift automatic
circuit breakers are unintentionally triggered.
For protection purposes the ETR 400.2 P can only be run with a GFCI. The
machine is standard equipped with a PRCD protective switch integrated in the
cord.
Attention!
!
The PRCD protective switch must not lay in water.
PRCD protective switches must not be used to switch
Before starting your work, check the proper function
uxiliary Handle
3
2
The auxiliary handle (A) can be adjusted according to the application. For this,
use the supplied Allen wrench SW6 to loosen the screw (1). Set the auxiliary
handle to the desired position and tighten the screw again.
Electrical Connection
Cross section in sq. mm
1.5
-
50 m
the tool on and off.
by pressing the TEST button.
Before the initial commissioning, the auxiliary
1
handle (A) must be installed on the gearbox
housing with the cylinder screw (1), lock washer
(2) and washer (3).
2.5
40 m
80 m
22