5.5.3
Room requirements
Tab.85
Indoor unit
Refrigerant
installation
charge
height
0.6 m
factory -
maximum
1 m
factory -
maximum
1.8 m
factory -
maximum
2.2 m
factory -
maximum
5.5.4
Installing the mounting bracket
Fig.118
5.5.5
Refrigerant pipes connection
Fig.119
3
7797831 - v04 - 07122022
Uni
MOSE20
MOSE25
t
2.39 - 4.47
2.39 - 4.47
2
m
0.86 - 1.61
0.86 - 1.61
2
m
0.27 - 0.50
0.27 - 0.50
2
m
0.18 - 0.33
0.18 - 0.33
2
m
MW-6020019-01
MW-6020016-01
Warning
The room in which the R32 refrigerant air conditioner is installed
cannot be smaller than specified in the table below. This is to
prevent potential safety problems caused by leakage of refrigerant
from the indoor unit.
MOSE35
3.06 - 5.38
1.10 - 1.94
0.34 - 0.60
0.23 - 0.40
See also
Additional refrigerant charge, page 124
Caution
The wall must be solid and suitable to support 20 kg.
1. Position the mounting bracket on the wall.
2. Make sure that the mounting bracket is level.
3. Determine the position of the holes.
4. Drill holes in the wall for the mounting bracket.
5. Secure the mounting bracket to the wall.
6. Use a spirit level to make sure that the mounting bracket stays
horizontal and is perpendicular to the vertical direction.
If installed incorrectly, there may be water leakage from the indoor unit
when the air conditioner is operating in cooling mode.
1. Take out the refrigerant pipes connection.
2. Secure condensate pipe, refrigerant pipes and electric cables together
using plastic cable ties.
3. Wrap all pipes and cables with tape to prevent condensation.
5 Installation
MOSE50
MOSE70
13.94 - 24.47
17.65 - 30.40
5.02 - 9.17
6.35 - 10.94
1.55 - 2.83
1.96 - 3.38
1.04 - 1.89
1.31 - 2.26
en