en Installation instructions
Place the angle bracket for the flue duct on the
9.
centre line so that it is flush with the ceiling.
Measure and mark the drill holes for the fastening
screws.
Drill the holes.
10.
Insert the wall plugs flush with the wall.
11.
Screw on the angle bracket for the flue duct.
12.
Preparing the appliance
When starting up in air extraction, install the back-
▶
flow flap, if required.
Installing the appliance
WARNING ‒ Risk of injury!
Components inside the appliance may have sharp
edges.
Wear protective gloves.
▶
ATTENTION!
If the glass flap is opened too far and the hinges over-
stretch, the appliance may be damaged.
Do not push the glass flap upwards beyond the end
▶
stop.
Do not overstretch the hinges.
▶
28
Hook on the appliance.
1.
Open the glass flap.
2.
Hold the glass flap at the lower edge and pull it
‒
upwards.
Slide the opened glass flap slightly to the rear.
‒
a The hinges click into place and the glass flap re-
mains open.
Align the appliance horizontally using screws and
3.
screw it in tightly.
Attach and screw in the two additional safety
4.
screws.
Insert the grease filter.
5.
To avoid causing damage, do not bend the grease
filters.