Télécharger Imprimer la page

Elica PRF0129429 Instructions De Montage Et D'utilisation page 5

Publicité

Les langues disponibles

Les langues disponibles

Before installing the hood
1.
For the most efficient air flow exhaust, use a straight run
or as few elbows as possible.
CAUTION: Vent unit to outside of building, only.
2.
At least two people are necessary for installation. Wear
gloves to protect against sharp edges.
3.
Fittings material is provided to secure the hood to most
types of walls/ceilings, consult a Qualified Installer, check
if they perfectly fit with your cabinet/wall.
4.
Do not use flex ducting.
5.
COLD WEATHER installations should have an additional
backdraft damper installed to minimize backward cold air
flow and a nonmetallic thermal break to minimize
conduction of outside temperatures as part of the
ductwork. The damper should be on the cold air side of
the thermal break.
The break should be as close as possible to where the
ducting enters the heated portion of the house.
6.
Make up air: Local building codes may require the use of
Make-Up Air Systems when using Ducted Ventilation
Systems greater than specified CFM of air movement.
The specified CFM varies from locale to locale. Consult
your HVAC professional for specific requirements in your
area.
When used in recirculation mode, To Reduce the Risk of
Fire and Shock use only conversion kit Model: Carbon
Filter
Use
The hood has been made for use in the internal recirculating
filtering version.
Cooking fumes and steam are aspirated inside the hood,
filtered and cleaned, passing through the fat filter/s and the
carbon filter/s that MUST be supplied with the hood.
Installation
Specialised personnel must carry out
both the electrical and the mechanical
installation.
Do not cut a joist or stud unless absolutely necessary. If a joist
or stud must be cut, then a supporting frame must be
constructed.
Fittings material is provided to secure the hood to most types
of walls/ceilings.
However, a qualified technician must verify suitability of the
materials in accordance with the type of wall/ceiling.
Before making cutouts, make sure there is proper clearance
within the ceiling or wall for exhaust vent.
Hood installation height above cooktop is the users
preference.
CAUTION:
FOR GAS RANGES
INSTALLATION: MOUNT THIS HOOD SO
THAT THE BOTTOM EDGE IS AT 30" (76,2
CM) ABOVE THE COOKING SURFACE.
FOR ELECTRIC RANGES INSTALLATION:
MOUNT THIS HOOD SO THAT THE
BOTTOM EDGE IS NOT LESS THAN 30"
(76,2 CM) AND NO MORE THAN 30" (76,2
CM) ABOVE THE COOKING SURFACE.
HOUSEHOLD USE. PLEASE, READ
INSTALLATION MANUAL FOR SPECIFIC
APPLICATION.
Check your ceiling height and the hood
height maximum before you select your
hood.
Consult last pages of this manual for installation
instruction and electrical connection steps.
Operation
5

Publicité

loading

Ce manuel est également adapté pour:

Ees320ssEasy