18 Troubleshooting
18.1 Safety notices
18.2 Fault indications
caso EMCG 34 PRO
This chapter provides you with important notices with regard to
operating the device. Observe the following notices to avoid
dangers and damages:
► Only qualified electricians, who have been trained by the
manufacturer, may carry out any repairs on electrical
equipment.
► Improperly performed repairs can cause considerable
dangers for the user and damages to the device.
In the event of a fault, an error code will appear in the display; it
describes the cause of the fault.
Error code
E-1
Excessive temperature within cooking
chamber
The overheating cut-out terminated the current
program at a cooking chamber temperature of
230°C .
Press the Pause/Cancel button to acknowledge
this fault.
The device can be re-activated after the cool
down phase.
E-3
Sensor fault
The device has detected an error on a sensor
and has terminated the current programme.
Press the Pause/Cancel button to acknowledge
this fault.
► If error messages continue to appear after an extended
waiting period and restarting the device, then the device will
need to be sent to Customer Service to be inspected.
Attention
Description
Please note
Troubleshooting
116