rough framing - before appliance installation
EN
Before framing your appliance, determine vent requirements before deciding the fi nal location of the appliance.
After rough framing, place the appliance in its fi nal position.
minimum framing
Ref
E
F
J
*L
4.2
front frame installation
Remove screws from appliance, add the front frame, and reinstall the screws.
24
W415-4121 / B / 04.20.23
L
E
F
J
TLV50
TLV62
20 1/8" (51.1cm)
65 13/16" (167.2cm)
77 13/16" (197.6cm)
Optional - Appliance does not need to be elevated above fl oor
73" (185.4cm)
Before framing an appliance, ensure
to install the fi restop fi rst.
note:
The TLV series requires a
minimum enclosure/ceiling
height, as illustrated
(dimension L), measured
from the bottom of the
appliance. For temperature
requirements, this area must
be left unobstructed. Some
venting confi gurations that
require more vertical rise will
require a larger enclosure
to provide minimum verti-
cal clearance between vent
pipes and combustibles.
TLV74
89 13/16" (228.1cm)
91" (231.1cm)