Original instructions.
© COPYRIGHT 2015, DESOUTTER HP2
7SJ UK
All rights reserved. Any unauthorized use
or copying of the contents or part thereof
is prohibited. This applies in particular to
trademarks, model denominations, part numbers
and drawings. Use only authorized parts. Any
damage or malfunction caused by the use of
unauthorised parts is not covered by Warranty or
Product Liability.
STATEMENT OF USE
Product is designed for installing and removing
threaded fasteners in wood, metal and plastic.
No other use permitted.
For professional use only.
DATA
(See page 4).
Noise level: < 70 dB(A) (EN 60 745).
Vibration level: < 2.5 m/s² (EN 60 745).
Declaration of noise and vibration emission
All values are current as of the date of this
publication. For the latest information please visit
desouttertools.com.
These declared values were obtained by
laboratory type testing in accordance with the
stated standards and are suitable for comparison
with the declared values of other tools tested
in accordance with the same standards. These
declared values are not adequate for use in risk
assessments and values measured in individual
work places may be higher. The actual exposure
values and risk of harm experienced by an
individual user are unique and depend upon
the way the user works, the workpiece and the
workstation design, as well upon the exposure
time and the physical condition of the user.
We, Desoutter, cannot be held liable for the
consequences of using the declared values,
instead of values reflecting the actual exposure,
in an individual risk assessment in a work place
situation over which we have no control.
This tool may cause hand-arm vibration
syndrome if its use is not adequately managed.
An EU guide to managing hand-arm vibration
can be found at http://www.pneurop.eu/uploads/
documents/pdf/PN3-02-NV_Declaration_info_
sheet_0111.pdf
We recommend a programme of health
surveillance to detect early symptoms which
may relate to noise or vibration exposure, so that
management procedures can be modified to help
prevent future impairment.
REQUIREMENTS
These tools need to be used with controllers
ESP1-HT/ESP2-A.
Dedicated clamping area for torque
reaction.
(See page 4).
ELECTRICAL CONNECTION
(See page 6).
ACCESSORIES
(See page 7).
A wide range of accessories are available and
suitable items should be selected from the
relevant Desoutter Catalogue.
OPERATING INSTRUCTIONS
SLB tools are ESD (ElectroStatic
Discharge) certified screwdrivers,
according to requirements of IEC
EPA
61340-5-1 standard.
A
≤ 1s
>3s
To remove a previously tightened fixing,
reposition the switch in position unscrewing
(Fig.B) and increase the torque setting (Fig. C).
Again press the tool into the fixing and it will
unscrew.
12 / 60
English
B
C
02/2015
Nm

Publicité