5. TYPE OF SYSTEM
Install the suitable corrugated pipes according to the indicated scheme, taking into account the type of terrain.
2
1
3
12
The system must be powered at 230 V and 50 Hz,
passing
through
magnetothermal line switch (for cables over 100
!
m in length with a cross sec�on of 2.5 mm²).
The en�re system must be connected to the
ground.
LEGEND
1. Electronic control programmer (230 Vac 3G x 1.5 mm² power cable) with plug-in radio receiver
2. Flashing light and antenna (2G x 0.5 mm² cable and RG 58 50 Ω coaxial cable)
3. Photocell (4G x 0.5 mm² receiver cable | 2G x 0.5 mm² transmi�er cable)
4. Actuator with founda�on box (230 Vac 4G x 1.5 mm² power cable | 3G x 0.5 mm² encoder)
5. Stop bollard
6. Transmi�er photocell (2x0.5 mm²)
7. Column prepared for internal photocell
8. Electric lock (2G x 1 mm² cable)
9. Ground stop bollard
10. Key switch
11. Transmi�er
12. Inspectable underground box
ATENTION
The cable specifica�ons refer to a maximum length of 15 m. For longer measurements, the cable sec�on must be determined
considering the power consump�on of the connected devices and following the guidelines of the CEI EN 60204-1 standard.
8
6
4
5
7
a
0.03
A
differen�al
4
9
GB - 23
10
6
5
11
FOX 724 | FOX 730
3
7
12
Pic. 4