Télécharger Imprimer la page

Siemens SIMATIC RF200 Manuel Système page 158

Masquer les pouces Voir aussi pour SIMATIC RF200:

Publicité

Plots de lecture/écriture
5.8 SIMATIC RF285R
 
 
 
Degré de protection selon EN 60529
Chocs selon EN 60721-3-7, classe 7 M2
Vibration selon EN 60721-3-7, classe 7 M2
 
Forme, dimensions et poids
Dimensions (l x H x P)
Poids
Mode de fixation
Longueur du câble, maximale
Mode de signalisation
 
Normes, spécifications, homologations
MTBF
5.8.7
Homologations
FCC information
Siemens SIMATIC RF285R (MLFB 6GT2821-7AC12) FCC ID NXW-RF285R
This device complies with part 15 of the FCC rules. Operation is subject to the following two
conditions:
(1) This device may not cause harmful interference, and
(2) this device must accept any interference received, including interference that may cause
undesired operation.
Caution
Any changes or modifications not expressly approved by the party responsible for compliance
could void the user's authority to operate the equipment.
Note
This equipment has been tested and found to comply with the limits for a Class A digital
device, pursuant to part 15 of the FCC Rules.
These limits are designed to provide reasonable protection against harmful interference
when the equipment is operated in a commercial environment. This equipment generates,
uses, and can radiate radio frequency energy and, if not installed and used in accordance
with the instruction manual, may cause harmful interference to radio communications.
Operation of this equipment in a residential area is likely to cause harmful interference in
which case the user will be required to correct the interference at his own expense.
158
en service
au transport et à l'entreposage
 
-20 ... +55 °C
-25 ... +85 °C
IP65
300 m/s
2
 20 m/s
2
200 × 80 × 140 mm
1,8 kg
4 vis M4
≤ 1,5 Nm
RS232 : 30 m max.
4 LED
 
18 ans
Manuel système, 11/2022, J31069-D0227-U001-A12-7719
6GT2821-7AC12
SIMATIC RF200

Publicité