Température ambiante
•
•
Degré de protection selon EN 60529
Chocs selon EN 60721-3-7, classe 7 M2
Vibration selon EN 60721-3-7, classe 7 M2
Forme, dimensions et poids
Dimensions (L x l x H)
Poids
Mode de fixation
Longueur du câble, maximale
Mode de signalisation
Normes, spécifications, homologations
MTBF
5.5.6
Homologations
FCC information
Siemens SIMATIC RF250R (MLFB 6GT2821-5AC10) FCC ID NXW-RF250R
Siemens SIMATIC RF250R (MLFB 6GT2821-5AC40) FCC ID NXW-RF250R
This device complies with part 15 of the FCC rules. Operation is subject to the following two
conditions:
(1) This device may not cause harmful interference, and
(2) this device must accept any interference received, including interference that may cause
undesired operation.
Caution
Any changes or modifications not expressly approved by the party responsible for compliance
could void the user's authority to operate the equipment.
Note
This equipment has been tested and found to comply with the limits for a Class A digital
device, pursuant to part 15 of the FCC Rules.
These limits are designed to provide reasonable protection against harmful interference
when the equipment is operated in a commercial environment. This equipment generates,
SIMATIC RF200
Manuel système, 11/2022, J31069-D0227-U001-A12-7719
en service
au transport et à l'entreposage
Plots de lecture/écriture
•
-20 ... +70 °C
•
-25 ... +85 °C
IP65
500 m/s
2
200 m/s
2
50 × 50 × 30 mm
60 g
2 vis M5
≤ 1,5 Nm
•
RS422 : 1000 m max.
•
RS232 : 30 m max.
LED tricolore
430 ans
5.5 SIMATIC RF250R
6GT2821-5AC10
6GT2821-5AC40
137