Tenzo SL65-HC-XX Manuel D'installation & Guide Du Propriétaire page 7

Table des Matières

Publicité

STEP #5
S
LIDE THE SHOWER ARM COMPONENT ALL THE WAY ON THE CONNECTOR
TO SCREW THE PRESSURE SCREWS AGAINST THE CONNECTOR
SURE THERE IS NO LEAKAGE AND THAT THE SHOWER ARM IS PROPERLY FIXED
ÉTAPE #5
G
'
LISSER LE BRAS DE DOUCHE JUSQU
AU FOND DU CONNECTEUR
VISSER LES VIS DE PRESSION CONTRE LE CONNECTEUR
'
'
'
S
ASSURER QU
IL N
Y A AUCUNE FUITE ET QUE LE BRAS EST SOLIDEMENT FIXÉ
. U
A
SE THE
LLEN KEY
. D
O A QUICK CHECK TO MAKE
.
. U
A
TILISER LA CLÉ
LLEN POUR
. F
AIRE UNE VÉRIFICATION POUR
.
Rev_02/2018
13
T
ROUBLE SHOOTING
No t T e mp e r e d (Ho t o r C o l d o n l y )
S upply of hot and cold water lines are rev ers ed.
Lo w p r e s s u r e o r n o w a t e r
1 - W ater hose pinched or s queezed from behind.
2 - W ater pres s ure inferior to 35 ps i.
(Thermos tatic v alv e)
3 - Debris at the entrance of the check v alv e.
4- Hard water
T h e r a i n s h o w e r h e a d c o n t i n u o u s l y d r i p s a f t e r u s e
1 - The rain s hower head is placed horizontally .
2 - The handle of the rain s hower head v alv e does not
clos e properly .
W a t e r t e mp e r a t u r e t o o h o t o r t o o c o l d a t t h e t w e l v e o 'c l o c k p o s i t i o n
1 - The temperature of y our water heater is not
adjus ted to 60 ° C (140 ° F).
2 - Debris at the entrance of the check v alv e.
3 - Temperature knob is in the wrong pos ition.
C h a n g e i n t e mp e r a t u r e
1 – Pres sure lower than 35 ps i.
2 - W ater line ov erloaded.
Interchange the water s upply hos es
Make s ure that the hos es are well pos itioned and are
not pinched or s queezed any where.
A - Water s upply from the city .
No pos s ible s olution
B - W ater s upplied by well.
Increas e the pres s ure of y our pump.
Remov e the faucet from the wall, dis connect the hot
and cold connectors from the v alv e and remov e all dirt
and debris .
Soak the thermostatic cartridge in a (50/50) s olution of
water and v inagar, for 12h. Cons ult the cartridge
remov al manuel for ins trutions before s tarting .
Place y our rain s hower head at an angle to allow the
water to drain.
Contact Tenzo for a cartridge replacement .
Make the adjus tment of the temperature of y our water
heater.
Remov e the faucet from the wall, dis connect the hot
and cold connectors from the v alv e and remov e all dirt
and debris .
Contact Tënzo for pos s ible adjus tement of the
thermos tatic cartridge.
No s olution pos s ible.
Feed directly into the main s upply .
Rev_02/2018
14

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Sl65-hk-xxRu65-hc-xxRu65-hk-xxQu65-hc-xxQu65-hk-xxNu65-hc-xx ... Afficher tout

Table des Matières