ATEX RANGE
TROUBLESHOOTING
PROBLEM
The shaft does not turn
Loss of performance
The tool vibrates
abnormally
The shaft does not stop
despite the start lever not
being pressed
ENGLISH
20
OPERATING AND MAINTENANCE MANUAL
CAUSE
Tool start lever not fully
pressed
The pressure or flow rate of
the air supply line is zero or
insufficient
Overly low temperature
Tool faulty
Incorrect position of the
rotation inverter
Tool start lever not fully
pressed
The pressure or flow rate of
the air supply line is zero or
insufficient
Insufficient lubrication
Dirty filter
Incorrect position of the
rotation inverter
Tool faulty
The tool is not well supported
on the screw
The accessories are not
connected correctly
The accessories are worn
Tool wear
Start lever jammed
SOLUTION
Press the start lever
Check the air supply line.
Operate in a higher
temperature environment
Contact an authorised service
centre
Reposition the rotation
inverter
Press the start lever
Check the air supply line.
Read the instructions and
lubricate the tool
Clean the filter
Reposition the rotation
inverter
Contact an authorised service
centre
Place the insert firmly on the
screw head
Connect the accessories
correctly
Replace the accessories
Contact an authorised service
centre
Disconnect the power supply