8. Electric Heat Kit Selection Table
Electric
Air
Heat Kit
Handler
Model
Model
AUX5KW
AUX7KW
24k
AUX10KW
AUX5KW
AUX7KW
36k
AUX10KW
AUX15KW
AUX5KW
AUX7KW
AUX10KW
48K/60K
AUX15KW
AUX20KW
NOTES:
Heat kit is an optional part, and it must have a separate power supply.
It is recommended that the electric heater kit should be installed in cold climate regions or when long piping
is used. Properly size the axillary heater per the table above.
Ampacities for MCA and Fuse/breaker include the blower motor.
Heat pump systems require a specified airflow. Each ton of cooling requires between 350 and 450 cubic feet
of air per minute(CFM).
MIN. Circuit Ampacity
Electric
Heat
(kW)
230VAC
5
28.3
7.5
40.7
10
53.2
5
29.8
7.5
42.2
54.7
10
15
42.2+36.9
31.8
5
7.5
44.8
56.7
10
15
44.8+36.9
20
56.7+49.9
MAX. Fuse or Breaker
(HACR) Ampacity
208VAC
230VAC
25.9
30
37.2
45
48.5
60
27.4
30
38.7
45
49.9
60
38.6+33.8
45+40
29.4
35
40.7
45
51.9
60
50+40
40.7+33.8
51.9+45.2
60+50
18
Fan Speed Tap
208VAC
2
3
30
40
x
50
x
x
30
50
x
50
x
x
40+35
x
x
30
45
x
55
x
x
50+35
x
x
60+50
x
x
4
5
x
x
Available
Not available
x