CAUTION
Danger of crushing
▶ Keep hands away from the
2
Push the handle forwards until the
roller drive makes contact with the
pressing attachment.
3
Turn the handle clockwise until the
stop position is reached. The
hydraulic valve is closed.
28
pressing attachment.
4
Actuate the pump lever alternately
upwards and downwards until you
can hear the switch-off noise and the
pump lever becomes easy to move.
✓ The pressing procedure is
complete.
5
Turn the handle anticlockwise until
the stop position is reached. The
hydraulic valve is opened.
6
Push the handle backwards.
7
Release the pressing attachment
from the pressfitting.
An automatic pressure device
ensures that the pressed joint is
completely finished. For safety
reasons, the automatic pressure
device does not switch on until 20%
of the press capacity is reached. The
pressing procedure can be
interrupted up to that point by turning
the handle anticlockwise and thereby
opening the hydraulic valve. The
pressing procedure can no longer be
interrupted after the automatic
pressure device has switched on.
The pump lever must continue to be
operated until the pressing procedure
has finished.