Installation and Operation Manual
X-TMF-GF40-Series-MFC-eng
Part Number: 541B195AAG
October, 2017
2-18 Using the MultiFlo
TM
Configurator
The MutliFlo Configurator application is used to configure the gas and
range of the GF40 Series devices.
The MultiFlo Configurator application allows communication to GF40
Series devices through personal computer with serial COM Port and a
Windows XP or Windows 7 operating system. It's primary function is to
configure gas and flow ranges within defined standard configurations.
Flow ranges are configured to the Nitrogen equivalent.
Using the MultiFlo Configurator software, configure the gas and flow rate
according to Table 2-1.
The MultiFlo Configurator interfaces to the GF40 Series device through
RS485. There are various ways to connect the device regardless of device
configuration. Devices may be connected through the diagnostic port using
cables in one of the following MultiFlo Configurator Kits.
MultiFlo
TM
MultiFlo kits are available in the following configurations:
778Z010ZZZ
A331710003
214F027AAA
778Z012ZZZ
A331710003
214F027AAA
641Z117AAA
778Z013ZZZ
A331710003
214F027AAA
641Z117AAA
124Z170AAA
778Z014ZZZ
A331710003
214F027AAA
641Z117AAA
124Z171AAA
Connect the MultiFlo cable adapter 2.5-mm jack to the diagnostic port on the
top of the device. See Figure 2-5.
Connect the RS485 end of the converter to the 15-pin RS485 end of the
MultiFlo Cable Adapter.
Connect the USB end of the converter to the USB Port of a laptop or PC.
The latest MutliFlo Configurator Software and Databases and MultiFlo
Configurator Quick Start Guide are available on the Brooks Instrument
website at: www.BrooksInstrument.com/MultiFlo. Please reference the
MultiFlo Configurator Quick Start Guide for installation and operation
details. Download the MultiFlo Configurator software into your computer
Configurator Accessory Kits:
Basic MultiFlo Configurator Kit
Cable Assembly 2.5mm
USB-RS485 converter with DB-9 female
GF0xx RS485 Analog/Profibus
Configurator Kit w/Power Supply 24 Vdc
Cable Assembly 2.5mm
USB-RS485 converter with DB-9 female
Power Supply 24 Vdc with DB-15 female
GF0xx EtherCAT
Configurator Kit w/Power Supply 24 Vdc
Cable Assembly 2.5mm
USB-RS485 converter with DB-9 female
Power Supply 24 Vdc with DB-15 female
Cable, Power, EtherCAT to DB-15 male
GF0xx DeviceNet
Configurator Kit w/Power Supply 24 Vdc
Cable Assembly 2.5mm
USB-RS485 converter with DB-9 female
Power Supply 24 Vdc with DB-15 female
Cable, Power, DeviceNet to DB-15 male
Section 2 Installation
®
Brooks
GF40 Devices
®
MultiFlo
®
MultiFlo
TM
MultiFlo
2-7

Publicité

loading