Dimensions in mm
X = fixing dimensions
Flange socket
Drilling template for flange sockets
Inlet
Plug
Coupler
Wall socket without switch
Plug and socket system for industrial use 63 A,
3-pole, 4-pole and 5-pole, GHG 524
1
Technical data
1.1
Plug and socket GHG 524
Rated voltage UN
Rated current
Back-up fuse
without thermal protection
Switching capacity
Wall socket with switch
Perm. ambient temperature
(Special versions permit deviating temperatures)
Perm. storage temperature in original packing
Protection category acc. to IEC/EN 60529
with closed and secured hinged cover
Insulation class acc. to IEC/EN 61140
Cable entries:
Wall socket with switch
suitable cables and test torques of the
pressure screw
Seal 1+2
min.
1 2
3
max.
Seal 1
min.
1 2
3
max.
Test torque for screw in thread cable entry
(1)
The tests of clamping ranges and torque values were performed with metal mandrel. The clamping range can
vary by using cables with different manufacturing tolerances and material properties. Please use a suitable
combination of seals in the intermediate area, so that the cap nut can be tightened in future maintenance
work on the cable entry.
Wall socket without switch
Plug / Coupler
Supply terminal:
Wall socket with switch
Wall socket without switch
Plug
Flange socket / Coupler
Test torques:
Cover screws
Terminals
Self-cutting screws size 4
Self-cutting screws size 5
Switch connection screw
Weight: (catalogue version)
Wall socket without switch
Wall socket with switch
Plug
Flange socket
Inlet
Coupler
up to 690 V, 50/60 Hz
max. 63 A
max. 63 A gG
AC 22
415 V / 63 A
500 V / 63 A
690 V / 63 A
-20° C to +40° C (catalogue version)
-20° C to +40° C
IP 66 (catalogue version)
I - is complied with by the devices
(catalogue version)
1 x M50 + 1 x blanking plug M50
Ø
24.0
(1)
28.0
28.0
(1)
35.0
7.5 Nm
3 x drilling M40 (2 x top, 1 x bottom)
incl. 1 x enlargement gland M50
Ø 19 - 28 mm
Cross section
1 x 2.50 - 25 mm²
(with cable lugs 1 x 35 mm
1 x 2.50 - 35 mm²
1 x 4.00 - 16 mm²
(with cable lugs 1 x 25 mm
1 x 2.50 - 35 mm²
2.5 Nm
4.5 Nm
2.0 Nm
3.0 Nm
2.0 Nm
3-pole
GHG 524 4.
approx. 5.40 kg
GHG 524 2.
approx. 1.80 kg
GHG 524 7 .
approx. 0.70 kg
GHG 524 8.
approx. 1.20 kg
GHG 524 9.
approx. 0.80 kg
GHG 524 3.
approx. 1.10 kg
GB
Nm
6.0
7.0
5.0
7.0
Stripped wire
length
13 mm
)
2
12 mm
12 mm
)
2
12 mm
4-pole
5-pole
approx. 5.50 kg
approx. 5.60 kg
approx. 1.90 kg
approx. 2.00 kg
approx. 0.75 kg
approx. 0.80 kg
approx. 1.30 kg
approx. 1.40 kg
approx. 0.90 kg
approx. 1.00 kg
approx. 1.20 kg
approx. 1.30 kg
Wall socket with switch