DISPLAY
DATA
Strt
StAn
no
AP.Ch
PrES
oroL
Sto P
no
ProS
invE
Fot 1
no
AP.Ch
Fot 2
CFCh
Ch
no
Ft.tE
no - Si
FUNCTION
Activation inputs function
This menu allows selecting input operation modes (see chapter 4.4)
Standard mode
Start inputs from terminal board are disabled.
Radio inputs operate in standard mode
Open/Close command
Manned operation
Timer mode
Stop Input
The input STOP is not available (ignored by the control unit)
The input STOP stops the gate: pressing the command START the gate
continues the motion
The command STOP stops the gate: at the next START the gate starts moving
in the opposite direction
Photocell 1 input
This menu allows enabling the input for type 1 photocells, that is to say,
photocells active both during the opening and closing phase
Input disabled (ignored by the control unit)
Input enabled
Photocell 2 input
This menu allows enabling the input for type 2 photocells, that is to say,
photocells non active during the opening phase
nput enabled even at standstill gate too: the opening movement does not
start if photocell is interrupte
Input enabled for the closing phase only
WARNING: if you select this option, you must disable photocell test
Input disabled (ignored by the control unit)
Test of the photocells
In order to achieve a safer operation for the user, the unit performs a
photocells operational test, before a normal working cycle.
If no operational faults are found, the gate starts moving.
Otherwise, it will stand still and the flashing light will stay onfor 5 sec.
The whole test cycle lasts less than one second.
StAn
47
DEFAULT MEMO
StAn
no
no
CFCh
no