3.2 - MOUNTING THE RACK
Release the motor and turn the gate completely open. Fix all the rack elements to the gate, making sure that they stand at the same
height than the motor pinion. The rack MUST BE positioned 1 or 2 mm over the pinion of the motor all the gate length.
WARNING: If the gate is very heavy we suggest to use an M4 22x22 rack (code. 162324)
3.3 - FIXING OF THE MOTOR
Check the following points:
1. the motor must be on a levelled surface and perfectly parallel to the gate
2. the distance between pinion and rack must be 1 or 2 mm. If needed, adjust the 4 grains
3. the rack must be trued up with the pinion of the motor
4. the minimum distance between the maximum overall of the gate and the case of the pinion of the motor must be of at least 5 mm
Check the above indicated conditions and proceed fixing the 4 bolts D anchoring the motor to the plate.