9 - INSTALLATION MENÙ (SEt)
This menu allows you to perform the movements of the gate
needed during installation.
The automatic learning procedure enables to save run limits
based on data collected by the encoder.
The manual handling procedure allows to control the gate in hold
to run mode in special cases such as during
installation/maintenance or a malfunction of the photocells or
edges
CAUTION: ATTENTION: before proceeding, make sure
to position the mechanical stops and the limit sensors
correctly.
1. Press and hold the OK key until the display shows
2. Release the OK key: the display shows
OK key if it is desired to exit this menu)
and i to select the menu
3. Use the keys
APPr
manual handling or
procedure of the run limits.
4. Press OK to start the selected procedure
10 - EMERGENCY MAN PRESENT OPERATION
This operational mode can be used to move the gate in Man Present mode in particular cases, such as installation/maintenance or in the
case of malfunctioning of photocell, edge, limit switches or encoder.
To start the "emergency" dead man operating mode activate the start command (START) for 3 seconds.
Strt
Note: if the
parameter is set as
open and closed directions alternatively (unlike the normal Man Present mode).
Emergency man present mode ends after 10 seconds of the gate not moving.
-SEt
ESC
(only press the
Mov
to activate
to start the automatic learning
StAn
, the Start command (from the terminal block or remote control) moves the gate in the
9.1 - AUTOMATIC LEARNING OF THE RUN
LIMITS
CAUTION: to perform the self-learning procedure it is
necessary to disable the ADI interface by means of the
menu i.Adi . If some safeties are controlled by means of the
ADI module, they will not be active during the self-learning
NOTE: during the self-learning the slowdown in the limit switch
area is not active. To slowdown the motor press the button i of
the control unit or activate the command START P. (cabled or
radio) when the gate comes near to the limit switch.
5. The display shows the control panel and the automatic
learning procedure of the run limits starts.
5.1
Gate closing is activated until the closing limit switch is
reached.
5.2
Gate opening is activated until the opening limit switch
is reached.
5.3
Gate closing is activated until the closing limit switch is
reached.
6. At the end of the automatic learning procedure, the control
unit automatically exits this menu and returns to normal
operation.
9.2 - MANUAL HANDLING
WARNING: when this procedure is activated the
safeties are not active.
MAn
5. The display shows
key to open the gate or the i button to
6. Press and hold the
close the gate
7. Release the button to stop the gate
8. To exit this menu, press OK.
NOTE: If the motor is inactive for more than one minute
the procedure terminates automatically.
42