Operateur electromecanique 230v irreversible a cremaillere pour portails coulissants jusqu'a 1200 kg de poids
Masquer les pouces Voir aussi pour AYROS-230V:

Publicité

Les langues disponibles

Les langues disponibles

L
Power phase 230 VAC
N
Neutral 230 VAC
B1 - B2
Flashing light 230VAC - 40W
B3 - B3
Courtesy light
START - Open command for connecting
M1
traditional devices with N.O. contact
START P. - Pedestrian open command for
M2
connecting traditional devices with N.O. contact
M3
STOP command. N.C. contact
M4
Common (-)
M5
Photocell 1. N.C. contact
M6
Photocell 2. N.C. contact
M7
Type 1 edges. N.C. contact
M8
Type 2 edges. N.C. contact
M9
Accessories common (-)
24VAC supply for photocells and other
M10
accessories
M11
Accessory power common (-)
24VAC supply - photocell/optical edge TX for
functional Test.
M12
Connect power supply cables of photocells
transmitter between terminals M11 and M12
A1
Antenna shield
A2
Antenna
ADI
ADI module interface
RECEIVER
Plug-in receiver
FUSE
10A
MAINS
It shows that the control unit is power supplied
It shows that there is an overload on accessories
OVERLOAD
power supply
4.9 - PLUG IN RECEIVER
PD19 control unit is suitable for plugging in a MRx receiver
having a high-sensitivity super-heterodyne architecture.
WARNING: it is necessary to turn off the control unit
power before doing the operations mentioned here below.
Pay attention to the way you connect the removable
modules.
MRx module receiver is provided with 4 channels and each of
them is suitable for a command of PD19 control unit:
• CHANNEL 1
START
• CHANNEL 2
PEDESTRIAN START
• CHANNEL 3
STOP
• CHANNEL 4
COURTESY LIGHT
NOTE: Before programming 4 channels and function
logics read carefully the instructions of MRx.
4.10 -
ADI INTERFACE
The ADI (Additional Devices Interface) interface of the control
unit PD19 allows the connection to V2 optional modules.
Refer to V2 catalogue or to the technical sheets to see which
optional modules with ADI interface are available for this control
unit.
WARNING: Please read the instructions of each single
module to install the optional modules.
For some devices, it is possible to configure the mode for
interfacing with the control unit; in addition, it is necessary to
enable the interface so that the control unit can process the
signals arriving from the ADI device.
i.Adi
Please refer to the
interface and access the device configuration menu.
ADI devices use the display of the control unit to issue alarms or
display the configuration of the control unit.
The device connected to the Adi interface is able to signal to the
control unit three alarm signals, which are displayed on the
control unit display as follows:
PHOTOCELL ALARMS
the gate stops moving, when the alarm stops opening
restarts.
-
EDGE ALARM
the lower segment comes on
inverts motion of the gate for 3 seconds.
-
STOP ALARM
both segments start flashing
the gate stops and cannot restart until the alarm stops.
• SLAVE - segment steadily lit: it is used by the optional module
SYNCRO to indicate that the control unit is configured as
SLAVE.
39
programming menu to enable the ADI
-
the upper segment comes on
:
:
: