INSTALLATION
OUTSIDE AIR SUPPLY
INSTALLING IN A MOBILE HOME / TRANSPORTABLE
BUILDING)
Depending
on
your
construction, outside air may be necessary for
optimal performance. Your stove is approved to be
installed with an outside air intake (69FAK) which
is necessary for a mobile home / transportable
building. You can purchase the 69FAK through your
heater dealer. Installation instructions are supplied
with the air intake kit.
ATTENTION:
DO NOT VENT UNDER ANY PORCH, DECK,
AWNING, OR IN ANY SEMI ENCLOSED OR
ROOFED AREA. DOING SO MAY RESULT IN
UNPREDICTABLE AIRFLOW AT THE VENT
CAP UNDER CERTAIN CONDITIONS AND CAN
AFFECT THE PERFORMANCE OF YOUR STOVE,
AS WELL AS, OTHER UNFORESEEABLE ISSUES.
SECURING APPLIANCE TO THE FLOOR
Use the designated holes to secure the unit to the
floor.
WARNING! DO NOT INSTALL IN SLEEPING
ROOM.
CAUTION!
THE
STRUCTURAL
OF THE MOBILE HOME / TRANSPORTABLE
BUILDING FLOOR, WALL, AND CEILING/ROOF
MUST BE MAINTAINED.
WHEN INSTALLED IN A MOBILE HOME /
TRANSPORTABLE
MUST BE GROUNDED DIRECTLY TO THE STEEL
CHASSIS AND BOLTED TO THE FLOOR.
(OPTIONAL, UNLESS
location
and
Exhaust
Pipe
Fresh Air
Intake
INTEGRITY
BUILDING,
THE
STOVE
In addition to the previously detailed installation
requirements,
building installations must meet the following
home
requirements:
• This stove must be securely fastened to the floor
of the mobile home / transportable building
using two 1/4" lag bolts that are long enough to
go through both a hearth pad, if used, and the
floor of the home.
• The heater must be electrically grounded to the
steel chassis of the mobile home / transportable
building with 8 GA copper wire using a serrated
or star washer to penetrate paint or protective
coating to ensure grounding.
• Vent must be 3 or 4-inch "PL" Vent and must
extend a minimum or 36" (914 mm) above the roof
line of the mobile home / transportable building
and must be installed using a certified ceiling fire
stop and rain cap.
• When moving your mobile home / transportable
building, all exterior venting must be removed
while the mobile home / transportable building is
being relocated. After relocation, all venting must
be reinstalled and securely fastened.
• Outside Air is mandatory for mobile home /
transportable building installation. See Outside
Air Supply section and your dealer for purchasing.
• Check with your local building officials as other
codes may apply.
VENTING REQUIREMENTS
A compatible appliance adapter is required for the
proper venting installation of this unit. Purchase the
appropriate appliance adapter from your preferred
venting company prior to starting the ventilation
process.
7
mobile
home
/
© 2024 United States Stove Company
transportable