INTERIOR CHAMBERS
• Burn Pot - Periodically remove and clean the burn
pot and the area inside the burn pot housing. In
particular, it is advisable to clean out the holes in
the burn pot to remove any build up that may
prevent air from moving through the burn pot
freely.
• Heat Exchanger - There are three panels in the back
of the firebox that need to be removed in order to
clean the fly ash out of the heat exchanger.
a. Open the door and remove the burnpot.
b. Use the tab located at the top of the center
panel to lift the panel up and out of the unit.
© 2024 United States Stove Company
OPERATION INSTRUCTIONS
c. Lift the left and right panel up and out of the
unit.
d. Remove fly ash.
It is possible that creosote may accumulate in the
exhaust fan therefore, this must be brushed clean.
The exhaust fan can be found behind the left side
panel (facing the front of the heater), the circulation
fan can be found behind the right side panel. To
access the igniter, remove the air inlet tube and
cover (2 screws). The auger motor is located in the
center rear of the unit. Note: When cleaning, take
care not to damage the fan blades.
If a vacuum is used to clean your stove, we suggest
using the AV15E AshVac vacuum. The AV15E AshVac
is designed for ash removal. Some regular vacuum
cleaner (i.e. shop vacs) may leak ash into the room.
DO NOT VACUUM HOT ASH.
FAILURE
TO
THE CLEAN OUTS WILL RESULT IN POOR
PERFORMANCE OF THIS STOVE.