OPERATION INSTRUCTIONS
ROOM AIR FAN
When starting your stove the Room Air Fan will not
come on until the stove's heat exchanger warms up.
This usually takes about 10 minutes from start-up.
IF STOVE RUNS OUT OF PELLETS
This stove is fitted with a fuel level sensor that, when
connected to WiFi and detects a low fuel level, will
cause the display on the stove to flash and send a
notification to the accompanying app.
FUEL LEVEL
SENSOR
The fire goes out and the auger motor and blowers
will run until the stove cools. This will take 30 minutes
or longer depending on the heat remaining in
the appliance. After the stove components stop
running all lights on the display will go out and the
two digit display will show "E3"
REFUELLING
CAUTION:
• THE HOPPER AND STOVE TOP WILL BE HOT
DURING
OPERATION;
SHOULD ALWAYS USE SOME TYPE OF HAND
PROTECTION
WHEN
STOVE.
• DO NOT TOUCH THE HOT SURFACES OF THE
STOVE. EDUCATE ALL CHILDREN ON THE
DANGERS OF A HIGH-TEMPERATURE STOVE.
YOUNG CHILDREN SHOULD BE SUPERVISED
WHEN THEY ARE IN THE SAME ROOM AS
THE STOVE.
• NEVER PLACE YOUR HAND NEAR THE
AUGER WHILE THE STOVE IS IN OPERATION.
• WE RECOMMEND THAT YOU NOT LET THE
HOPPER DROP BELOW 1/4 FULL.
THEREFORE,
YOU
REFUELING
YOUR
15
WARNING:
• KEEP HOPPER LID CLOSED AT ALL TIMES
EXCEPT WHEN REFILLING.
• DO NOT OVERFILL HOPPER.
TAMPER WARNING
This wood heater has a manufacturer-set minimum
low burn rate that must not be altered. It is against
federal regulations to alter this setting or otherwise
operate this wood heater in a manner inconsistent
with operating instructions in this manual.
SHUTDOWN PROCEDURE
WARNING:
NEVER SHUT DOWN THIS UNIT BY UNPLUGGING
IT FROM THE POWER SOURCE.
Turning your stove off is a matter of pressing the
"POWER" button on the display board. The auger
motor will stop, and the blowers will continue to
operate until the internal firebox temperatures
have fallen to a preset level.
1.
Your stove is equipped with a high temperature
thermodisc. This unit has a manual reset
thermodisc. This safety switch has two functions.
A. To recognize an overheat situation in the stove
and shut down the fuel feed or auger system.
B. In
case
of
a
malfunctioning
blower, the high-temperature thermodisc will
automatically shut down the auger, preventing
the stove from overheating.
NOTE: On some units, once tripped, like a circuit
breaker, the reset button will have to be pushed
before restarting your stove. On other units the
thermodisc has no reset button and will reset
itself once the stove has cooled. The manufacturer
recommends that you call your dealer if this occurs
as this may indicate a more serious problem. A
service call may be required.
2. If the combustion blower fails, an air pressure
switch will automatically shut down the auger.
NOTE: Opening the stove door for more than
30 seconds during operation will cause enough
pressure change to activate the air switch, shutting
the fuel feed off. The stove will shut down and show
"E2" on the two digit display. The stove has to fully
shut down before restarting.
© 2024 United States Stove Company