Télécharger Imprimer la page

Vissani HVO170WF Manuel D'installation page 19

Publicité

Les langues disponibles

Les langues disponibles

Installation (continued)
Rotate blower unit counterclockwise 180°.
Before Rotation
Back of
Microwave
Gently remove the wires from the grooves. Reroute the wires
through grooves on other side of the blower unit.
Before Rerouting
Wires Routed Through Right Side
Roll the blower unit 90° so that fan blade openings are facing out
the back of the microwave.
Before Rolling
Back of
Microwave
Remove the knockout plates in the back of the unit with snips. (For
some models)
Back of mircrowave
After Rotation
Back of
Microwave
After Rerouting
Wires Routed Through Left Side
After Rolling
Back of
Microwave
Knockout Plates:
Snip all 4 webs on
each knockout panel
and remove the metal
knockouts for rear airflow.
Please take care to
remove any sharp edges
created from removing
the knockout plates.
Place the blower unit back into the opening.
AFTER: Fan Blade
Openings Facing Back
End B
CAUTION: Do not pull or stretch the blower unit wiring. Make
sure the wires are not pinched, and that they are properly
secured.
NOTE: The blower unit exhaust openings should match
exhaust openings on rear of microwave oven.
Secure the blower unit to the microwave with the original screw.
Replace the blower plate in the same position as before with the
screw. Make sure the screw is tight.
Attach the exhaust adaptor to the rear of the oven by sliding it
into the guides at the top center of the back of the oven.
Adaptor
Guide
Push in securely until it is in the lower locking tabs. Take care to
assure that the damper hinge is installed so that it is at the top and
that the damper swings freely.
19
End A
Blower Plate
Back of
Microwave
Blower Motor
Screw
Back of
Microwave
Guide
Locking Tabs