Installation (continued)
A1. ATTACHING THE MOUNTING PLATE TO THE
WALL
□
Attach the plate to the wall using toggle bolts. At least one wood
screw must be used to attach the plate to a wall stud.
NOTE: If the cabinet depth including the cabinet doors is
more than 13 in. then the unit must be spaced out from
wall using adequate materials supporting 150 Ib to allow
proper top vent air exhaust/intake.
in
□
Remove the toggle wings from the bolts.
□
Insert the bolts into the mounting plate through the holes
designated to go into drywall and reattach the toggle wings to
3 /4 in. (19 mm) onto each bolt.
To use toggle bolts:
Spacing for Toggles
More Than Wall
Thickness
Toggle Wings
Mounting
Toggle
Plate
Bolt
Wall
□
Place the mounting plate against the wall and insert the toggle
wings into the holes in the wall to mount the plate.
Bolt End
NOTE: Before tightening toggle bolts and wood screws, make
sure the bottom of the mounting plate touches the bottom of
the cabinet when pushed flush against the wall and that the
plate is properly centered under the cabinet.
CAUTION: Be careful to avoid pinching fingers between the
back of the mounting plate and the wall.
□
Tighten all bolts. Pull the plate away from the wall to help tighten
the bolts.
A2. USING TOP CABINET TEMPLATE FOR
PREPARATION OF TOP CABINET
□
You need to drill holes for the top support screws and a hole large
enough for the power cord to fit through.
□
e R ad the instructions on the TOP CABINET TEMPLATE.
□ Tape it underneath the top cabinet.
NOTE: Adjust top template accordingly if the microwave is
being spaced out from the wall due to cabinet depth (including
cabinet doors) of more than 13 in.
□ Drill the holes, following the instructions on the TOP CABINET
TEMPLATE.
CAUTION: Wear safety goggles when drilling holes in the
cabinet bottom.
A3. CHECKING BLOWER PLATE
□ Place the microwave in its upright position, with the top of the
unit facing up.
□ Check to see that the blower plate is correctly installed on the
unit.
12
Blower Plate