Important Safety Information
INSTALLATION WARNINGS
To avoid damage to your cabinets, check with your
builder or cabinet supplier to make sure that the
materials used will not discolor, delaminate or sustain
other damage.
MOBILE HOME – ADDITIONAL INSTALLATION
REQUIREMENTS:
The installation of this appliance must conform to the
Manufactured Home Construction and Safety Standard,
Title 24 CFR, Part 3280 (formerly the Federal Standard
for Mobile Home Construction and Safety, Title 24, HUD
Part 280).
When such standard is not applicable, use the Standard
for Manufactured Home Installations, ANSI A225.1/NFPA
GAS DANGER
Explosion hazard conditions will exist unless
you perform ALL of the following:
supply line.
gas pressure does not exceed 10" (25 cm) (range
tops)/14" (36 cm) (ranges) water column.
- Licensed heating personnel
- Authorized gas company personnel
- Authorized service personnel
Failure to do so can result in death, explosion, or re.
IMPORTANT: This installation must conform with all
local codes and ordinances. In the absence of local
codes, installation must conform with American National
Standard, National Fuel Gas Code ANSI Z223.1 / NFPA
54. - latest edition, or CAN/CGA B149 - latest edition. In
Canada, installation must conform to the current natural
Gas Installation /code, CAN 1-1.1-M81 and with local
codes where applicable. This appliance has been design-
certi ed according to ANSI Z21.1b-201 latest edition.
A statement of the maximum gas supply pressure in
accordance with the inlet pressure rating of the gas
appliance pressure regulator supplied.
IMPORTANT: Leak testing of the appliance must be
with 1/2-inch black iron pipe or a certi ed exible type
501A, ANSI A119.2.2–1982, or with local codes.
In Canada, the installation of this range must conform
with the current standards CAN/CSA-A240-latest
edition, CAN/CGA Z240.4.2, or with local codes.
MOBILE HOME INSTALLATIONS REQUIRE:
When this range is installed in a mobile home, it must
be secured to the oor during transit. Any method of
securing the range is adequate as long as it conforms to
the standards listed above.
The installation of appliances designed for recreational
park trailers must conform with state or other codes
or, in the absence of such codes, with the standard for
recreational park trailers, ANSI A119.5.
stove connector. To prevent gas leaks, put an approved
sealing compound which is resistant to lique ed
petroleum gases on all threaded connections.
ly should be located near the opening for this
appliance (see Figure 2, ranges only):
6.25"
10.5"
Shortest connection
from hard pipe stub
Area allows for ush installation
location to range
with through-the- oor connection
hook-up.
of pipe stub / shut-off valve.
Types of Gas
NATURAL GAS:
after proper conversion, for use with LP gas.
model/serial rating plate has information on the types
of gas that can be used. If the types of gas listed do not
include the type of gas available, check with the local
gas supplier.
LP GAS CONVERSION:
Conversion must be done by a quali ed service technician.
the gas speci ed on the model/serial rating plate for
use with a different gas without consulting the serving
gas supplier.
— 9 —
2"
Area allows for
ush installation
with through-the-
4"
wall connection
2"
of pipe stub /
shut-off valve
and rear wall
120V outlet.
Figure 2