Caution!
This appliance may only be connected to a mains supply with 230 V/400 V ~ 50/60 Hz.
Always connect the earth cable.
Please observe the wiring diagram.
The connection box is located on the back of the hob casing. To open the lid, use a medium-sized
screwdriver. Insert it into the slots and open the cover.
Mains
230V~50/60Hz
400V~ 50/60Hz
* calculated with the simultaneity factor according to the standard EN 60
335-2-6
Setting up the configurations:
For the different connection types, use the brass bridges in the box next to the terminal.
Single-phase 230V~1P+N:
Place a bridge between terminals 1 and 2.
Connect the earth to the earth connection, the neutral conductor N to terminal 4 and phase L to one
of the terminals 1 or 2.
Two-phase 400V~2P+N:
Connect the earth to the earth connection, the neutral conductor N to terminal 4, phase L1 to
terminal 1 and phase L2 to terminal 2.
Connection
1 phase + N
2 phases + N
Cable diameter
3 x 2.5 mm²
4 x 2.5 mm²
17
Protection
Cable
H 05 VV - F
H 05 RR - F
H 05 VV - F
H 05 RR - F
class
25 A *
16 A *