7.2.
Adjusting the operating mode evaporator
The cabin is active in the operating mode "evaporator" (see section 6.2).
Information: First, set the desired temperature (e.g. 50 °C) and then the humidity (e.g. 55%). For physical
reasons, the sum from both values cannot exceed 110 °C.
Temperature:
1 x
The display shows "Raum-Temp." (cabin temp.). The desired cabin temperature is adjusted by the
Plus- or Minus-button. Temperature adjustment is made in one degree steps between 30 and 65 °C.
Humidity:
2 x
The display shows "% Rel. Lf" (% rel. humidity). The desired humidity is adjusted by the Plus- or
Minus-button. Adjustment is made in one percent steps between 10 and 99 percent.
Blower: [
only with blower function = YES] (see section 5.2).
3 x
The display shows "blower". Use the Plus-button to switch the blower on and the
Minus-button to switch it off.
7.3.
Adjusting the operating mode infrared radiator
The cabin is active in the operating mode "infrared radiator" (see section 6.2).
Cabin temperature:
1 x
The display shows "Raum-Temp." (cabin temp.) - the desired cabin temperature is adjusted by the
Plus- or Minus-button. Temperature adjustment is made in one degree steps between 20 and 50 °C.
Blower: [
only with blower function = YES] (see section 5.2).
2 x
The display shows "blower". Use the Plus-button to switch the blower on and the
Minus-button to switch it off.
EN
31