4.5. Appliance switch (Switch off):
There is an appliance switch on the back of the power unit. It is
provided to disconnect the electrical system from the mains supply
(Fig. 7).
The appliance switch can be disconnected if necessary and an
external ON/OFF switch can be connected instead (see Fig. 6).
4.6. Mounting the temperature sensor:
At a distance of 150 - 170 cm from the sauna heater (Fig. 8), drill a hole with a diameter of 7 mm into
the sauna ceiling (preferably in the middle of a profile board).
Pull the 5-pole silicone cable (5 x 0.5 mm) provided through the opening and connect it in separate 1 to 1
connections (i.e. 1 to 1, 2 to 2 etc.) with the sensor and the power unit.
Fix the sensor to the sauna ceiling with two screws (Fig. 10).
Fig. 8
4.7. Connecting the light:
Drill a hole into the roof at the desired point for the light connecting cable.
The light can be positioned anywhere in the sauna, but not directly above the rising hot air stream from
the sauna heater.
Fig. 9
Fig. 7
Fig. 10