Contents
1.0
Relationship to the authorities .................. 11
2.0
3.0
Safety ...........................................................12
4.0
Installation ..................................................13
5.0
Assembly .................................................... 14
6.0
7.0
8.0
Recycling ..................................................... 14
Product:
On all our products there is a label
Jøtul
Room heater fired by solid fuel
indicating the serial number and
year. Write this number in the
Standard
:
Minimum distance to adjacent combustible materials:
Minimum distance to adjacent combustible materials:
place indicated in the installation
Emission of CO in combustion products
:
Flue gas temperature
:
Nominal heat output
:
Efficiency
instructions.
:
Operation range
:
Fuel type
:
Operational type
:
The appliance can be used in a shared flue.
Always quote this serial number when
Country
Classification
Certificate/
Approved by
standard
contacting your retailer or Jøtul.
Norway
Klasse II
SP Sveriges Provnings- och
Sweden
SP
OGC
Forskningsinstitut AB
SP Swedish National
Testing and Research
EUR
Intermittent
EN
Institute
Follow user`s instructions. Use only recommended fuels.
Montage- und Bedienungsanleitung beachten.
Verwenden Sie nur empfohlenen Brennstoffen.
Respectez les consignes d'utilisation. Utilisez uniquement
les combustibles recommandés.
Serial no: Y-xxxx, Year: 200x
Manufacturer:
221546
Jøtul AS
POB 1441
N-1602 Fredrikstad
Norway
Serial no.
1.0 Relationship to the
authorities
The Jøtul FS 173 is a freestanding product using the Jøtul
I 520 as the burn chamber, and can be positioned against
combustible walls at the distances described in Fig. 1.
The installation of a fi replace must be carried out in
compliance with national laws and regulations. All local
ordinances must also be complied with when products
are installed.
Contact your local building authorities regarding restrictions
and installation requirements.
The product may not be used until it has been inspected
and approved by qualifi ed personnel.
The product has been tested and documented as a freestanding
stove in accordance with EN 13240.
The approval label for the freestanding product comes with
the installation instructions for the surround. Cut off the label
and attach it outside the top rear plate.
2.0 Technical data for
the burnchamber
Material:
Finish:
Type of fuel:
Max. log length:
Smoke outlet:
Flue pipe dimension:
Weight approx.:
Optional extras:
Product dimensions, clearances
Technical data in accordance with EN 13240
Nominal heat output:
Efficiency:
CO emissions (13% O2):
CO emissions (13% O2):
OGC emissions (13% O2):
Dust emissions (13% O2):
Flue gas temperature:
Flue gas flow rate:
Chimney draught, EN 13229:
Recommended draught
with smoke outlet:
Fuel consumption:
Kindling quantity;
Max. kindling:
Operation:
Intermittent operation means normal use of a fireplace. This
means that to refuel the fire, you add more wood as soon as the
previous load of wood has burned down to embers.
ENGLISH
Cast iron
Black paint
Wood
50 cm
Top outlet or 45° rotated
position for rear outlet.
Ø 150 mm/177 cm 2 cross section
110 kg + 261 kg
Floor plate NO, SE and DK, Floor
plate DE, Adapter for outside
air connection and Kit for Ø 80
fresh air intake tube.
See Fig. 1
7 kW
77%
0.07%
884 mg/Nm3
60 mg/Nm3
14 mg/Nm3
305°C
7.1 g/s
12 Pa
16-18 Pa
2.3 kg/h
nominal 1.7 kg
3.4 kg each time and 3.8 kg/h
Intermittent
11