3.5 Air circulation
There must be a flow of air between the burn chamber and the
surround. This is to ensure that any build-up of heat inside the
surround is not too great. NB: It is extremely important not to
cover air openings. See Fig. 1 for distances.
The amount of combustion air for Jøtul's products is approximately
25-40 m
3
/h.
3.7 Steel chimney
If a top-mounted steel chimney is used, a semi-insulated chimney
must be installed all the way down to the insert.
Fig. 2
Then fit the steel chimney in accordance with the manufacturer's
instructions.
•
The insert must be connected to a chimney and flue pipe
approved for solid fuel fireplaces with a flue gas temperature
of 305°C.
•
The cross-sectional area of the chimney must be at least
that of the flue pipe. Ø 150 mm/177 cm2 cross-sectional area.
•
Several solid fuel products can be connected to the same
chimney system if the cross-sectional area of the chimney is
adequate. Contact your local building authorities regarding
restrictions and installation requirements.
•
The chimney must be connected in accordance with the
installation instructions of the chimney supplier.
•
Make sure that the flue pipe rises all the way up to the
chimney.
•
Please note that it is extremely important for connections to
have a degree of flexibility.
The recommended chimney draught is 16 - 18 Pa.
4.0 Installation
NB: Before installing the fireplace, check it carefully for any signs
of damage.
NB: The product is heavy! Ask someone to help you when
positioning and installing it.
NB: Read the Installation and Operating Instructions for the Jøtul
I 520 (Cat. no. 10046368) and Jøtul FS 173 (Cat. no. 10048557)
carefully before installing the fireplace!
Use the acrylic sealant provided for all joints
4.1 Prior to installation
The basic product comes in two packages:
1. Burn chamber.
2. Soapstone units with mounting sections.
NB: Check the product for signs of damage when you
unpack it.
Preparations
Before installation, it is necessary to decide:
•
Where the smoke outlet is to be located.
•
Possible use and location of external air supply.
Refer to manuals for installation of the parts.
Smoke outlet
Before starting installation work, decide whether a rear or top
outlet will be used. The product is delivered from the factory with
the smoke outlet positioned for a top outlet.
4.2 Preparations for the burnchamber
(Jøtul I 520)
NB: Before installing the fireplace, check it carefully for any signs
of damage. The product is heavy! Ask someone to help you when
positioning and installing it.
Read the Installation and Operating Instructions for the Jøtul I 520
(Cat. no. 10046368).
ENGLISH