5.3.2 Replacing the fuel filters
This unit is equipped with two fuel filters; these two filters must be replaced at the same time. Fuel will run out during the operation;
use a suitable container.
1.
Close the fuel tap (A4).
2.
Place a suitable container underneath the fuel filter (A16).
3.
Note the direction of assembly for the fuel filter
4.
Pinch the mounting clips (C2) and remove the hoses.
5.
If fitted, unscrew the screws for the retaining clip (C4).
6.
Dispose of the worn fuel filter.
7.
Observing the direction of fitting, fit a new fuel filter between the hoses by pinching the mounting clips.
8.
If fitted, screw the screws for the retaining clip back in
9.
Proceed in the same way for the second fuel filter.
10. Open the fuel tap and check that there are no leaks.
11. All traces of fuel should be wiped off with a clean cloth and the fuel tap closed again.
5.3.3 Replacing the air filter
1.
Undo the wheel (D1) and remove the air filter cover (D2).
2.
Remove the wing nut (D3) and the filter element (D4).
3.
Replace the filter element with a new one.
4.
Check that the rubber seal (D5) is in good condition; replace it if necessary.
5.
Carefully refit the filter element, wing nut, and then the air filter cover, screwing the wheel back in.
5.3.4 Clean the generating set and its retention container
To ensure it operates correctly, the inside and outside of the unit must be cleaned regularly. If the unit is installed inside, always
check that the installation is clean and in good condition. If the unit is being used outside (building sites, dusty, muddy or densely
wooded areas, corrosive environment, etc.), it must be cleaned more frequently.
IMPORTANT
1.
Wash the outside of the generating set using water with a mild detergent added (e.g. car shampoo).
A cleaning foam may be used and wiped off using a soft, absorbent cloth. Stubborn stains may be removed using a suitable solvent (white
spirit or equivalent) and wiped off using a soft, absorbent cloth.
2.
Rinse with clear fresh water to remove any trace of cleaning product.
3.
Open the top cover (A17) and access door on the generating set (A18).
4.
Check that there is no fluid or debris in the retention container (A5) : if necessary, pump the fluid into a suitable container.
Any fluids present in the retention container (rainwater, engine oil or fuel) must be recycled or disposed of according to the applicable
local regulations.
5.
Close the top cover and access door on the generating set.
6.
Apply an rustproofing product to damaged areas, change defective parts and damaged labels if necessary.
Only use original parts and consult an agent if necessary.
6 Transporting and storing the generating set
6.1
Transport and handling conditions
The unit should be handled gently and sudden movements should be avoided. Ensure that the place where it is to be stored or
used is carefully prepared beforehand. Before any fixed installation on a trailer or inside a vehicle, consult one of our approved
agents.
Before transporting the unit, take the following necessary precautions:
1.
Check that the routes to be used are smooth and drivable. If it proves necessary to use uneven roads, drain the fuel into a
container before setting off.
2.
Check that the bolts are correctly tightened, close the fuel tap (if fitted) and disconnect the battery (if fitted).
3.
The unit should always be transported in its normal operating position; never lay it on its side. Ensure that the unit cannot
fall from the vehicle carrying it, but without exerting too much force (risk of damaging the unit).
6.2
Storage conditions
This procedure for storing the unit or protecting it over the winter must be respected if it is not used for a period of up to 1 year. For
longer periods of storage, it is recommended to contact your nearest agent or to start up the unit for a few hours every year,
ensuring that the storage procedure is respected afterwards.
1.
Start the unit and allow it to operate until it runs out of fuel.
2.
With the fuel tap open, replace the fuel filter (A16).
The fuel circuit will drain, ensuring that the unit remains in good condition.
3.
Close the fuel tap (A4).
4.
Disconnect the battery (A2).
5.
Top up the oil.
6.
Replace the air filter (A25).
7.
Clean the unit and cover it with a protective cover.
8.
Store it in its normal position, in a clean, dry and well ventilated area.
Material damage
[Generating set]
If the retention container level is too high, this may irreparably damage the generating set:
check there is no fluid present before each start-up, and clean as often as is necessary. Use
of high pressure cleaning equipment is prohibited as this may seriously damage the unit. Any
major scratches must be repaired (please contact your nearest agent).