3 Installation requirements and
Installation requirements and clearances
clearances
Installation requirements and clearances
3.1 Appliance dimensions
This model series is 27'' (686 mm) in depth and features
brushed stainless-steel canopy, telescopic chimney flue,
with LED lights.
Note: The transition is centered horizontally.
IMPORTANT: The hood needs to be centered over the
cooking surface for best performance.
Installation requirements and clearances en-us
3.2 Clearances
This appliance requires the ducting to be vented to the
outside. It cannot be used in conjunction with a
recirculation unit.
Hood installation height above a cooktop, rangetop or
range can vary. To obtain the necessary installation height
above a cooktop, rangetop or range, consult the
appliance's installation manual.
*Follow cooking appliance manufacturer's
recommendations.
3.3 Hood width
This hood is intended only for an island type installation.
¡
There is a minimum distance of 12" (305 mm) from the
back wall to the edge of the island hood.
The hood width should be no less than the width of the
¡
cooking surface. For proper performance, the housing
must cover the entire cooking surface.
For proper performance, the hood must be centered
¡
horizontally above the cooking surface. Where space is
not restricted, a wider hood can be used to increase
capture area.