en-us Installation
Route the make-up air damper harness through the
2.
strain relief to the terminal block.
The make-up air kit hot and return connections can
use either terminal connection. There is no polarity
requirement for the two pin terminal block.
Secure the ground wire with the green T-20 ground
3.
screw.
5.6 Built-in remote control accessory
(optional)
Before you begin, read these instructions carefully. It is
recommended that the remote control be wired to the
hood after the hood is installed.
IMPORTANT: Cutting off a connector to the appliance or
to the extension cable kit will void the warranty.
REMCPW parts included:
Remote control (1)
¡
30 ft. extension harness (1)
¡
Installing the remote control
Prepare the cutout in the wall or similar surface for
1.
installation as shown below (view is shown facing wall).
16
Access the hood's wiring. Route the 30 ft. extension
2.
harness through the strain relief to the square mounting
clip until it clicks.
Route the 30 ft. extension harness through the cutout
3.
and connect the harness to the back of the remote
control bracket.
Press the bracket inside the cutout. Drill a ¼" (6 mm)
4.
tap hole through the bracket holes into the wall. Mount
the bracket to the wall using the four (4) screws
provided.