3.5 - MOTOR OVERRIDING SYSTEM
In case of absence of current, the gate can be released by
operating on the motor:
1. Open the hatch of the lock J in front of the motor
2. Insert the key K in the lock and turn clockwise to open
the hatch of the release on the side
3. Insert the key L into the hole and turn clockwise until
reached the limit switch
4. At this point you can manually move the gate
To restore the automation, proceed as follows:
1. Bring the gate to the fully closed position
2. turn the key L anticlockwise until reached the limit
switch, then draw it out
3. turn the key K anticlockwise closing the hatch of the
lock, then draw it out
4. Close the lock with the hatch J
3.6 - INSTALLATION LAYOUT
5
6
7
Motor
1
Transmitter
2
Receiving module
3
Photocells
4
Flashing light
5
Key or digital switch
6
7
Pillar photocells
LENGTH OF THE CABLE
Power supply 230V
Photocells (TX)
Key switch
Photocells (RX)
Flashing light
Antenna (integrated into the flashing light)
4
< 10 metres
3G x 1,5 mm
2 x 0,5 mm
4 x 0,5 mm
2 x 0,5 mm
2 x 1,5 mm
RG174
L
2
from 10 to 20 metres
2
3G x 1,5 mm
2 x 0,5 mm
2
4 x 0,5 mm
2
2
2 x 0,5 mm
2 x 1,5 mm
2
RG174
K J
1
3
from 20 to 30 metres
2
3G x 2,5 mm
2 x 0,5 mm
2
4 x 0,5 mm
2
2
2 x 0,5 mm
2 x 1,5 mm
2
RG174
2
2
2
2
2
ENGLISH - 35 -