Télécharger Imprimer la page

Parkside PMFW 310 F4 Traduction Des Instructions D'origine page 8

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 28
e) Maintain power tools and accessories. Check
for misalignment or binding of moving parts,
breakage of parts and any other condition
that may affect the power tool's operation. If
damaged, have the power tool repaired
before use. Many accidents are caused by
poorly maintained power tools.
f) Keep cutting tools sharp and clean. Properly
maintained cutting tools with sharp cutting
edges are less likely to bind and are easier to
control.
g) Use the power tool, accessories and tool bits
etc. in accordance with these instructions,
taking into account the working conditions
and the work to be performed. Use of the
power tool for operations different from those
intended could result in a hazardous situation.
h) Keep handles and grasping surfaces dry,
clean and free from oil and grease. Slippery
handles and grasping surfaces do not allow for
safe handling and control of the tool in unex-
pected situations.
5. Service
a) Have your power tool serviced by a qualified
repair person using only identical replace-
ment parts. This will ensure that the safety of
the power tool is maintained.
PMFW 310 F4
Appliance-specific safety instructions
for grinders
WARNING!
Dusts from materials such as leaded paint,
some types of wood and metal can be
harmful to your health.
Lead or lead-containing materials may not be
processed.
Contact with or inhalation of these dusts can
represent a health hazard for the person
operating the appliance and other people
in the vicinity.
Wear safety goggles and a protective dust
mask!
Residual risks
Even if you operate this power tool properly, there
will still be residual risks. The following risks can
occur in the context of the design and construction
of this power tool:
a) Lung damage, if no suitable breathing protection
is worn.
b) Hearing damage, if no suitable hearing protec-
tion is worn.
c) Damage to health caused by vibrations if the
appliance is used for extended periods or is not
properly used and maintained.
WARNING!
The power tool creates an electromagnetic
field during operation. This field can, in certain
circumstances, impair active or passive medical
implants. To reduce the risk of fatal injuries,
we recommend that people with medical
implants consult their doctor and the manu-
facturer of the medical implant before oper-
ating this machine.
GB │ IE
 5

Publicité

loading