OPERATING INSTRUCTION FOR ELECTROMECHANICAL BARRIER
GB
Lock and release operations must be performed with motor
not running. It is recommended to keep outside barrier's
operating range. The unlocked barrier may be subject to
independent movements.
Note: (only for UP2EH-UP4EH) To power off the barrier, cut off
mains and disconnect the batteries (if installed).
RELEASE INSTRUCTION
In case of faulty operation or power failure, insert the key and turn
clockwise by 60 degrees, put to the end and rotate anticlockwise
by 60° and remove it. The barrier remains release.
To lock, repeat the operation.
[1] Barrier locked = cylinder projecting.
[2] Barrier released = cylinder retracted.
GENERAL SAFETY PRECAUTIONS
The following precautions are an integral and essential part of
the product and must be supplied to the user.
Read them carefully as they contain important indications for
the safe installation, use and maintenace.
These instruction must be kept and forwarded to all possible
future user of the system.
This product must be used only for that which it has been ex-
pressely designed.
Any other use is to be considered improper and therefore dan-
gerous.
The manufacturer cannot be held responsible for possible da-
mage caused by improper, erroneous or unresonable use.
Avoid operating in the proximity of the hinges or moving mecha-
nical parts.
Do not enter the fi eld of action of the motorised door or gate
while in motion.
Do not obstruct the motion of the motorised door or gate as this
may cause a situation of danger.
Do not lean against or hang on to the barrier when it is moving.
Do not allow children to play or stay within the fi eld of action of
the motorised door or gate.
Keep remote control or any other control devices out of the reach
of children, in order to avoid possible involuntary activation of the
motorised door or gate. In case of breack down or malfunctioning
of the product, disconnect from mains, do not attempt to repair
or intervene directly and contact only qualifi ed personnel.
Failure to comply with the above may create a situation of
danger.
All cleaning, maintenance or repair work must be carried out by
qualifi ed personnel.
In order to guarantee that the system works effi ciently and
correctly it is indispensable to comply with the manufacturer's
indications thus having the periodic maintenance of the motori-
sed door or gate carried out by qualifi ed personnel.
In particular regular checks are recommended in order to verify
DITEC S.p.A.
Via Mons. Banfi , 3
21042 Caronno Pertusella (VA) - ITALY
Tel. +39 02 963911 - Fax +39 02 9650314
www.ditec.it - ditec@ditecva.com
1
ON
OFF
that the safety devices are operating correctly. All installation,
maintenance and repair work must be documented and made
available to the user.