Thank you for purchasing a MN93, MN93A, C193, PAC93, E94 or MINI94 AC cur-
rent clamp or a MiniFlex MA193, MA194 or MA196, AmpFlex
flexible current sensor. This current sensor should only be used only with C.A
8XXX and PEL analysers. Not all sensors are suitable for all instruments. Contact
our customer service to make your choice.
For best service from your current sensor:
„ read these operating instructions carefully,
„ comply with the precautions for use.
WARNING, risk of DANGER! The operator must refer to these instruc-
tions whenever this danger symbol appears.
Current sensor protected by double insulation.
Application or withdrawal authorized on bare conductors carrying
dangerous voltages. Type A current sensor as per IEC 61010-2-032.
Must not be applied to or removed from bare conductors at dangerous
voltages. Type B current sensor as per IEC 61010-2-032.
The arrow indicates the phase of the current.
Battery.
The product has been declared recyclable after analysis of its life cycle
in accordance with the ISO 14040 standard.
The CE marking indicates compliance with the European Low Voltage
Directive (2014/35/EU), Electromagnetic Compatibility Directive
(2014/30/EU), and Restriction of Hazardous Substances Directive
(RoHS, 2011/65/EU and 2015/863/EU).
The UKCA marking certifies that the product is compliant with the re-
quirements that apply in the United Kingdom, in particular as regards
Low-Voltage Safety, Electromagnetic Compatibility, and the Restriction
of Hazardous Substances.
The rubbish bin with a line through it indicates that, in the European
Union, the product must undergo selective disposal in compliance with
Directive WEEE 2012/19/EU. This equipment must not be treated as
household waste.
Definition of measurement categories
„ Measurement category IV corresponds to measurements taken at the source of
low-voltage installations.
Example: power feeders, counters and protection devices.
„ Measurement category III corresponds to measurements on building installations.
Example: distribution panel, circuit-breakers, machines or fixed industrial devices.
„ Measurement category II corresponds to measurements taken on circuits directly
connected to low-voltage installations.
Example: power supply to electro-domestic devices and portable tools.