USE AND MAINTENANCE MANUAL
CHAPTER 4
Installation
DANGER - ELECTRIC SHOCK RISK
When installing, please ensure electropump is disconnected from electrical supply. Pumps in
this series are not suitable for use in a swimming pool and the relevant cleaning and servicing
operations.
DANGER
To prevent possible injuries to people, avoid inserting hands into the mouth of the pump if this is
connected to the electrical power supply.
Pentair CLEAROX pumps come with a check valve that prevents the delivery pipe from being drained and the fluid
from recirculating.
If the pump is fixed in a permanent location with rigid pipes, it is advisable to install a quick closing fitting in the
most convenient location to facilitate cleaning and maintenance.
The dimensions of the collection chamber should allow the insertion of the pump and reduce to the minimum the
start- up operations per hour (see LIMITATIONS - Technical data).
Use the handle provided to transport or lift the pump.
To use the pump for temporary applications, install a flexible pipe and connect it to the pump using a pipe holder. To
immerse the pump, use a rope and fix it to the handle.
The pumps should have a safety switch. Contact a specialised electrician.
FLAT SUCTION / PUMPING WATER WITH SOLIDS:
The pump is provided with a black ring at strainer for flat suction operations up to 2 mm. In case you need to pump
water containing solids up to 10mm you need to remove the ring from the pump base.