Clean the Surface
First clean the surface with a neutral detergent and wet cloth, and then wipe it with a dry cloth.
Warning! Do not touch the evaporator surface with bare-hand, or it could cause injury to your fingers.
TROUBLESHOOTING
Troubles
Possible Causes
Check if the power is connected securely.
Check if the water full code "Ft"
displayed.
The appliance is
Normal operation of the appliance
not running.
requires an ambient temperature in 5 ℃
– 35 ℃.
The doors or windows are not closed.
There are heat sources inside the room.
Not cool enough
The air exhaust hose is not connected or
in cooling mode
blocked.
Temperature setting is too high.
Air inlet or outlet is blocked.
The ground is not level or not flat enough.
Check if there are any parts loose and
Noisy
vibrating.
The sound comes from the flowing of the
refrigerant inside the appliance.
Code "E0" on the
Communication faults between the main
digital display
PCB and the display board.
Code "E1" on the
Room temperature sensor failed.
digital display
Code "E2" on the
Evaporator temperature sensor failed.
digital display
Code "Ft" on the
Water-full warning
digital display
TECHNICAL DATA
Below data for your operating reference
Model
Rated voltage
Rated frequency
Rated input
Rated current
Solutions
Connect the power properly.
Drain the water.
Check the room temperature. When the
room temperature is back to the range
(5 ℃ – 35 ℃), the appliance can be
operated normally.
Make sure all the windows and doors
are closed.
Remove the heat sources if possible.
Connect or clean the air exhaust hose.
Reset the temperature.
Clean the air inlet or outlet.
Place the appliance on a flat, level
surface if possible.
Secure and tighten the parts.
It is normal.
Check the wire harness of the display
board.
technician for repair.
Replace the room temperature sensor.
Contact authorized service technician
for repair.
Replace evaporator temperature sensor.
Contact authorized service technician
for repair.
Drain out the water.
PAC-127032.1
220-240V
50Hz
1005W
4.5A
- 14 -
Contact
authorized
service

Publicité