Physical (continued)
Depth
Four– and eight–hard-drive
systems
Twelve–hard-drive systems
Weight (maximum configuration)
Four–hard-drive systems
Eight–hard-drive systems
Twelve–hard-drive systems
Weight (empty)
Four–hard-drive systems
Eight–hard-drive systems
Twelve–hard-drive systems
Environmental
Temperature
Operating
Storage
Relative humidity
Operating
Storage
Maximum vibration
Operating
Storage
Maximum shock
Operating
61.02 cm (24.09 in)
66.46 cm (26.17 in)
16 kg (35.2 lbs)
22.5 kg (49.5 lbs)
29.0 kg (63.8 lbs)
13.6 kg (29.92 lbs)
13.5 kg (29.7 lbs)
15.85 kg (34.87 lbs)
10° to 35°C (50° to 95°F) with a maximum
temperature gradation of 10°C per hour
NOTE:
For altitudes above 2950 feet,
the maximum operating temperature
is derated 1ºF/550 ft.
–40° to 65°C (–40° to 149°F) with a maximum
temperature gradation of 20°C per hour
20% to 80% (noncondensing) with a maximum
humidity gradation of 10% per hour
5% to 95% (noncondensing)
0.26 G at 5–350 Hz for 15 min
1.54 G at 10–250 Hz for 15 min
One shock pulse in the positive z axis
(one pulse on each side of the system) of 31 G
for 2.6 ms in the operational orientation