Install Suction Hose to suction side of pump with included barb fittings and hose clamp (see Figure 4. page 4).
4.
Install the opposite end of suction hose to suction device with appropriate fittings (see Figure 4, page 4).
5.
Install Discharge Hose with nozzle to discharge side of pump with included barb fittings and hose clamp (see Figure 5a-b, page 5).
6.
Tighten each hose clamp to secure suction and discharge hoses to all barb fittings to prevent fluid leaks (see Figure 5c, page 5).
7.
Install nozzle boot bracket and
nozzle boot (Figure 9a - 9c).
8.
Insert nozzle boot bracket into slot
at top front of drum mount. Use
supplied zip-tie to secure bracket
to drum mount. (9a).
9.
Insert Nozzle Reservoir into Nozzle
Bracket and snap into opening.
10. Fill half full with water to
prevent DEF crystalization
in nozzle (9c).
Electrical Wiring
WARNING
Electrical wiring should be performed ONLY by a licensed electrician in compliance with local, state, and national electrical code NEC/ANSI/
NFPA 70, NFPA30, and NFPA 30A, as appropriate to the intended use of the pump. The pump must be properly grounded. Improper installation or
use of this pump can result in serious bodily injury, or death!
CAUTION
All pumps should operate at the rated voltage. Power should be supplied to the pump from a 15 amp circuit breaker. No other equipment should be
powered by this circuit. Wiring must be of sufficient size to carry the correct current for the pump. Voltage drop will vary with distance to pump and
size of wire; refer to the National Electrical Code (NEC), or local codes, for voltage drop compensation to be sure you are using the correct size wire for
your application.
WARNING
Be certain the power switch is "OFF" prior to connecting to the power source (AC or DC) to prevent unexpected starting of the motor. Unexpected motor
start can cause unintended discharge of fluid, creating a potential hazard.
AC Power Connection
WARNING
THIS PRODUCT MUST BE GROUNDED! DO NOT defeat the ground prong on the plug by using an adapter, or otherwise modifying the plug.
DO NOT plug this appliance into an ungrounded receptacle.
AC pumps come pre-wired for 120V AC, 60 Hz operation. These pumps are
equipped with a conventional 120V AC 3-prong grounded plug that can be
inserted into any conventional grounded receptacle. For safety and proper
operation, do not remove or in any way bypass the ground prong.
fillrite.com
DF SERIES
9a
INSTALLATION AND OPERATION MANUAL