Figure 5a
Figure 5b
Figure 5c
Drum / Barrel Installation
NOTICE
After initial assembly and installation, flush the entire dispensing system by pumping 5 – 10 gallons of DEF through it. This purges the system
of air, and insures any impurities that may have been in the system are washed out. Dispose of the DEF used to flush the system using approved
DEF handling procedures; do not return the fluid to the drum or tote, or use it in a vehicle.
WARNING
DO NOT overtorque the threaded collars that seal the barbed fittings to the inlet and outlet ports of the pump. The design features BSPP threads and
an o-ring seal that does not require excessive torque to provide a liquid / air tight seal.
1.
Adjust Drum Kit to fit a 30 or 55 Gallon drum by unlocking both wing nuts and sliding bracket to adjust for with drum diameter (Figure 7).
2.
Adjust length of suction tube to reach within 2" of the bottom of drum once tightened into bung adapter. Insert Drum Suction Tube (sold seperately,
item 6, page 11). Place Pump with Drum Bracket over drum lip. Compress sliding bracket to securely wrap around drum lip. Secure bracket by tight-
ening wing nuts (Figure 8).
fillrite.com
DF SERIES
O-RING
Figure 8
INSTALLATION AND OPERATION MANUAL
6.
Secure to cage with included tie strap (Figure 6a).
7.
Insert Nozzle Reservoir into Nozzle Bracket and snap into opening. Add
water to reservoir to prevent urea crystallization in nozzle (Figure 6a).
8.
Wrap Discharge Hose around the Pump Bracket behind Fill-Rite Ledge.
Final installation should look like the image below (Figure 6b):
Figure 6a
Figure 6b